|
|
Registros recuperados : 125 | |
22. | | RESTAINO, E.; VÁZQUEZ, D. Seminario internacional de mejoramiento de trigo en La Estanzuela. Revista INIA Uruguay, 2014, n. 38, p. 27-28 (Revista INIA; 38) Comité organizador: Silvia Germán, Martín Quincke, Daniel Vázquez, Marina Castro, Adriana García, Silvia Pereyra, Paula Silva, Ernesto Restaino
y Ana Silvera.Biblioteca(s): INIA La Estanzuela. |
| |
31. | | VÁZQUEZ, D.; WILLIAMS, P.C.; WATTS, B. NIR spectroscopy as a tool for quality screening. ln: International Wheat Conference, 7., 27 Nov-2 Dec 2005, Mar del Plata, AR Buck, H.T.; Nisi, J.E.; Salomón, N., ed. Wheat production in stressed environments : proceedings. Dordrecht: Springer, 2007. p. 527-533 (Developments in Plant Breeding ; 12) Donación S. Germán, 2007Biblioteca(s): INIA La Estanzuela. |
| |
32. | | GARÓFALO, L.; VÁZQUEZ, D.; SOULE, S. Incidencia de arabinoxilanos en la calidad panadera de harinas de trigo uruguayas. In: SEMINARIO INTERNACIONAL DE TRIGO, 2014, La Estanzuela, Colonia, UY. GERMÁN, S., et al. (Org.). 1914-2014, un siglo de mejoramiento de trigo en La Estanzuela: un valioso legado para el futuro: posters; resúmenes. La Estanzuela, Colonia, UY: INIA, 2014. p. 70.Biblioteca(s): INIA La Estanzuela. |
| |
33. | | GARÓFALO, L.; VÁZQUEZ, D.; SOULE, S. Incidencia de arabinoxilanos en la calidad panadera de harinas de trigo uruguayas. [Poster]. In: German, S.; Quincke, M.; Vázquez, D.; Castro, M.; Pereyra, S.; Silva, P.; García, A. (Eds.). Seminario Internacional "1914-2014: Un siglo de mejoramiento de trigo en La Estanzuela". Montevideo (UY): INIA, 2018. p. 254. (INIA Serie Técnica; 241).Biblioteca(s): INIA La Estanzuela. |
| |
35. | | VERA, G.; CONDON, F.; VÁZQUEZ, D. Soybean germplasm characterization for human consumption aptitude in Uruguay. [Caracterização do germoplasma de soja com aptidão ao consumo humano no Uruguai.] Original article. Brazilian Journal of Food Technology. 2024, Volume 27, Pages 1-17. https://doi.org/10.1590/1981-6723.04823 -- OPEN ACCESS. Article history: Received 19 Apr 2023, Accepted 21 Nov 2023, Publication in this collection 02 Feb 2024, Date of issue 2024. -- Correspondence: Vázquez, D.; Instituto Nacional de Investigación Agropecuaria (INIA), Agroalimentos,...Biblioteca(s): INIA Las Brujas. |
| |
Registros recuperados : 125 | |
|
|
| Acceso al texto completo restringido a Biblioteca INIA La Estanzuela. Por información adicional contacte bib_le@inia.org.uy. |
Registro completo
|
Biblioteca (s) : |
INIA La Estanzuela. |
Fecha actual : |
21/02/2014 |
Actualizado : |
07/07/2020 |
Tipo de producción científica : |
Trabajos en Congresos/Conferencias |
Autor : |
VÁZQUEZ, D.; WILLIAMS, P.C.; WATTS, B. |
Afiliación : |
DANIEL VÁZQUEZ PEYRONEL, INIA (Instituto Nacional de Investigación Agropecuaria), Uruguay. |
Título : |
NIR spectroscopy as a tool for quality screening. |
Fecha de publicación : |
2007 |
Fuente / Imprenta : |
ln: International Wheat Conference, 7., 27 Nov-2 Dec 2005, Mar del Plata, AR Buck, H.T.; Nisi, J.E.; Salomón, N., ed. Wheat production in stressed environments : proceedings. Dordrecht: Springer, 2007. |
Páginas : |
p. 527-533 |
Serie : |
(Developments in Plant Breeding ; 12) |
Idioma : |
Inglés |
Notas : |
Donación S. Germán, 2007 |
Contenido : |
Abstract: Simplicity of sample preparation, rapidity of the whole analytical procedure and small sample size requirements make near-infrared spectroscopy (NIRS) a very attractive tool for quality screening in wheat breeding programs. Although good results have been achieved for protein content, limited results have been obtained for other quality components such as protein functionality. The suitability of this technology to measure different quality components was studied using different sets of Uruguayan wheat samples n = 73–470#4;. Reference methods included protein composition, hardness, rheological variables and baking tests. Whole and ground wheat grain, and white flour samples were scanned with a Foss (NIRSystem) Model 6500 spectrophotometer. Differences among several math pretreatments for derivatives, gap and segment (smoothing) were
not critical to the quality of the calibration. Results were best when flour was scanned, but were also acceptable using ground wheat and even whole grain. Increasing the size of the scanned sample did not improve results, however duplicating the NIR spectra resulted in better calibrations. Calibration equations obtained were suitable to determine three independent quality components in one simple and fast operation, although with
different accuracies. Protein content was predicted with accuracy similar to that of the reference method (standard error of prediction = SEP = 0.16%; coefficient of determination = r2 = 0#5;99). Hardness calibration was successful only with the ground sample (SEP < 2%#6; r2 = 0#5;85). Results obtained for protein functionality variables had lower coefficients of determination but were sufficient for screening breeding lines. Coefficients of determination of calibration sets for the variables alveogram extensibility (L), MenosAbstract: Simplicity of sample preparation, rapidity of the whole analytical procedure and small sample size requirements make near-infrared spectroscopy (NIRS) a very attractive tool for quality screening in wheat breeding programs. Although good results have been achieved for protein content, limited results have been obtained for other quality components such as protein functionality. The suitability of this technology to measure different quality components was studied using different sets of Uruguayan wheat samples n = 73–470#4;. Reference methods included protein composition, hardness, rheological variables and baking tests. Whole and ground wheat grain, and white flour samples were scanned with a Foss (NIRSystem) Model 6500 spectrophotometer. Differences among several math pretreatments for derivatives, gap and segment (smoothing) were
not critical to the quality of the calibration. Results were best when flour was scanned, but were also acceptable using ground wheat and even whole grain. Increasing the size of the scanned sample did not improve results, however duplicating the NIR spectra resulted in better calibrations. Calibration equations obtained were suitable to determine three independent quality components in one simple and fast operation, although with
different accuracies. Protein content was predicted with accuracy similar to that of the reference method (standard error of prediction = SEP = 0.16%; coefficient of determination = r2 = 0#5;99). Hardness cali... Presentar Todo |
Palabras claves : |
NIR (NEAR INFRARED REFLECTANCE); QUALITY. |
Thesagro : |
ESPECTROSCOPIA INFRARROJA; FITOMEJORAMIENTO; INSPECCIÓN DE CALIDAD; TRITICUM. |
Asunto categoría : |
F01 Cultivo |
Marc : |
LEADER 02684naa a2200253 a 4500 001 1048187 005 2020-07-07 008 2007 bl uuuu u00u1 u #d 100 1 $aVÁZQUEZ, D. 245 $aNIR spectroscopy as a tool for quality screening. 260 $c2007 300 $ap. 527-533 490 $a(Developments in Plant Breeding ; 12) 500 $aDonación S. Germán, 2007 520 $aAbstract: Simplicity of sample preparation, rapidity of the whole analytical procedure and small sample size requirements make near-infrared spectroscopy (NIRS) a very attractive tool for quality screening in wheat breeding programs. Although good results have been achieved for protein content, limited results have been obtained for other quality components such as protein functionality. The suitability of this technology to measure different quality components was studied using different sets of Uruguayan wheat samples n = 73–470#4;. Reference methods included protein composition, hardness, rheological variables and baking tests. Whole and ground wheat grain, and white flour samples were scanned with a Foss (NIRSystem) Model 6500 spectrophotometer. Differences among several math pretreatments for derivatives, gap and segment (smoothing) were not critical to the quality of the calibration. Results were best when flour was scanned, but were also acceptable using ground wheat and even whole grain. Increasing the size of the scanned sample did not improve results, however duplicating the NIR spectra resulted in better calibrations. Calibration equations obtained were suitable to determine three independent quality components in one simple and fast operation, although with different accuracies. Protein content was predicted with accuracy similar to that of the reference method (standard error of prediction = SEP = 0.16%; coefficient of determination = r2 = 0#5;99). Hardness calibration was successful only with the ground sample (SEP < 2%#6; r2 = 0#5;85). Results obtained for protein functionality variables had lower coefficients of determination but were sufficient for screening breeding lines. Coefficients of determination of calibration sets for the variables alveogram extensibility (L), 650 $aESPECTROSCOPIA INFRARROJA 650 $aFITOMEJORAMIENTO 650 $aINSPECCIÓN DE CALIDAD 650 $aTRITICUM 653 $aNIR (NEAR INFRARED REFLECTANCE) 653 $aQUALITY 700 1 $aWILLIAMS, P.C. 700 1 $aWATTS, B. 773 $tln: International Wheat Conference, 7., 27 Nov-2 Dec 2005, Mar del Plata, AR Buck, H.T.; Nisi, J.E.; Salomón, N., ed. Wheat production in stressed environments : proceedings. Dordrecht: Springer, 2007.
Descargar
Esconder MarcPresentar Marc Completo |
Registro original : |
INIA La Estanzuela (LE) |
|
Biblioteca
|
Identificación
|
Origen
|
Tipo / Formato
|
Clasificación
|
Cutter
|
Registro
|
Volumen
|
Estado
|
Volver
|
Expresión de búsqueda válido. Check! |
|
|